CONTEC CA10M CO2 MonitorIntroduction
Capnograph adopts mainstream method to measure the end-tidal carbon dioxide, airway respiration rate and other parameters. It can detect pulmonary ventilation function and reflect the circulation and pulmonary blood flow condition, as well as indirectly reflect the alveolar ventilation, which is applicable for use in pre-hospital emergency transfer, emergency department, ICU, operating room, neonatology, respiratory department and other occasions. The application population is adult, pediatric and neonate patients. The Capnograph connects with patient’ respiratory tract by the airway adapter and breathing tube.
Features
1)End-tidal CO2 measurement function
2)Respiration rate measurement function
3)Over-limit alarm function for End-tidal CO2 and respiration rate
4)Low battery alarm function
Performance
End-tidal CO2 measurement:
1)Measurement range: 0 ~150mmHg
2)Resolution: 1mmHg
3)Accuracy:
0~40 mmHg:±2 mmHg
41~70 mmHg:±5% of readings
71~100 mmHg:±8% of readings
101~150 mmHg:±10% of readings
Respiration rate measurement:
1)Measurement range: 2rpm~150rbpm
2)Resolution: 1rpm
3)Accuracy: ±1rpm
Safety characteristic:
1)Device type: internally powered equipment
2)Degree of protection against electric shock: type BF applied part
3)Degree of protection against ingress of liquid: IPX2
Accessories
User Manual
Adult gas path adapter
Neonate gas path adapter (optional)
Physical Characteristic
Dimension: 55×52×59mm
Weight: 97g (with batteries)
Working environment
Temperature: 5℃~40℃
Relative humidity: 30%~ 75%, no condensation
Atmospheric pressure: 700hPa~1060hPa
Power supply: DC 3V (2 AAA dry batteries)
Input power: ≤1VA
Buy Safe product
The following FDA Disclaimer is required for all eBay listing in Healthcare category and is
included for REFERENCE: The sale of this item may be subject to regulation by the U.S.
Food and Drug Administration and state and local regulatory agencies. If the item is subject to FDA regulation, we will
verify your status as an authorized purchaser of this item before shipping of the item.
The Fingertip Pulse Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG)with the code 197923,
and certified by FDA of United States and CE,TUV of Europe.The Fingertip Pulse Oximeter that is FDA 510K Approved
Shipping:
1.
Clearance: we will ship your item(s) to your PayPal confirmed address.
Please leave your clear address, telephone, postal code / house number etc .
2.
It is the buyers' responsibility to consider duties, taxes and other extra charges by the government in your respective country.
3.
All items will be dispatched within 48 hours.
International Buyers - Please Note:
?
Import duties, taxes and charges are not included in the item price or shippingcharges. These charges are the buyer's responsibility.
?
Please check with your country's customs office to determine what these additional costs will be prior to bidding/buying.