-40%

Double Clamp Earth Resistance Tester Multi-function Soil Resistivity Measurement

$ 489.45

Availability: 100 in stock
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Condition: New
  • MPN: 54678790
  • Brand: VTSYIQI
  • All returns accepted: Returns Accepted
  • Country/Region of Manufacture: China
  • Clamp Caliber: Φ68mm
  • Electrode Distance Range: 1m-100m
  • Features: USB Interface
  • Data storage:: 2000 sets
  • Item must be returned within: 30 Days
  • Short-circuit Test Current: AC 20mA max
  • Return shipping will be paid by: Buyer
  • Test Frequency: 128Hz/111Hz/105Hz/94Hz(AFC)
  • LCD display area: 124mm×67mm
  • Open-circuit Test Current: AC 40V max
  • LCD Frame Dimension: 128mm×75mm
  • Restocking Fee: No

    Description

    Double Clamp Earth Resistance Tester Multi-function Soil Resistivity Measurement
    ETCR3200C Double Clamp Multi-function Grounding  Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. Apply digital processing technology, precision 4-wire method, 3-wire method and simple 2-wire method, selection method, double-clamp method to measure grounding resistance; Large caliber clamp design can measure the grounding system which using large grounding down lead, and can flexibly and accurately measure any grounding resistance value of various complex grounding conditions such as single point and mesh grounding. It is not necessary to disconnect any parallel grounding pole to measurement, maximize the convenience of measurement. Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement. The tester case is made of waterproof protection box, anti-collision, anti-drop, waterproof (protection grade IP65), strong and durable, and also equipped with a large-capacity rechargeable lithium battery pack, especially suitable for outdoor construction. Widely used in power, telecommunications, meteorology, oil fields, construction, lightning protection and industrial electrical equipment, such as grounding resistance, soil resistivity, grounding voltage, alternating current, leakage current measurement.
    Product Characteristics
    1

    2/3/4-wire method measure earth resistance,Range

    0.00Ω

    30.00kΩ
    2

    Selection method meausre earth resistance, Range: 0.00Ω

    3000Ω
    3

    Doule clamp method measure earth resistance,Range: 0.01~100Ω
    4

    Soil resistivity measurement, Range

    0.00Ωm

    9000kΩm
    5

    Earth voltage measurement,Range

    AC 0

    600V
    6

    AC current measurement, Range: 0.01mA

    600A
    7

    Data storage: 2000 sets
    8

    Alarm function: audible and visual alarm
    9

    CT size: Φ68mm
    10

    Waterproof case + Super large capacity lithium battery
    Technical Specifications
    Function
    Measure grounding resistance, soil resistivity; DC resistance, earth voltage, AC current , leakage current
    Power Supply
    DC 8.4V (rechargeable battery, continues standby 300 hours)
    Backlight
    Controllable screen backlight, suitable for dim places
    Measuring Mode
    Precise4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method measure grounding resistance
    Measuring Method
    2/3/4 pole measurement method: Change-pole method, measurement current 20mA Max
    Selection measurement method: Change-pole method, measurement current 20mA Max
    Double clamp measurement method: Non-connect mutual inductance method, measurement current 1mA Max
    Soil Resistivity: 4-pole measurement (Wenner method)
    DC resistance: Change-pole method
    AC current: Mutual inductance method(clamp)
    Earth Voltage: Average rectification(between P(S)-ES)
    Test Voltage Wave
    Sine wave
    Test Frequency
    128Hz/111Hz/105Hz/94Hz(AFC)
    Short-circuit Test Current
    AC 20mA max
    Open-circuit Test Current
    AC 40V max
    Electrode Distance Range
    1m-100m
    Display Mode
    4-digital large LCD display, with screen backlight
    Measuring Indicator
    During measurement, LED flash indicator, LCD countdown display
    LCD Frame Dimension
    128mm×75mm
    LCD display area
    124mm×67mm
    Instrument Dimension
    280mm(L)×260mm(W)×160mm(H)
    CT Size
    185mm(L)X115mm(W)X43mm(H)
    Test Wire
    4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
    Simple Test Wire
    2 wires: each for red 1.6m and black 1.6m
    Auxiliary Grounding Rod
    4PCS: Φ10mm×150mm
    Current Clamp
    2PCS :1 blue-black plug and 1 red-black plug
    Clamp Caliber
    Φ68mm
    Clamp Turn Ratio
    1000:1
    Clamp Lead Wire
    2m
    Measuring Rate
    AC current: about 2 times/second
    Earth Voltage: about 2 times/second
    Earth resistance: about 7 seconds/time
    Measuring Times
    Over 5000 times (Short-circuit test, interval time should be at least 30seconds)
    Line Voltage
    Measurement below AC 600V
    Communication Interface
    USB interface, storage data can be uploaded to computer, saved or printed.
    Communication Wire
    USB communication wire x1pcs, with length 1.5m
    Data Hold
    Data hold function: “HOLD” symbol display
    Data Storage
    2000 groups, “MEM” storage indicator, “FULL” symbol flash display storage is full
    Data Access
    Data read function: “READ” symbol display
    Overflow Display
    Exceed measuring range overflow function: “OL” symbol display
    Low Current Indicator of Current clamp
    Measurement with select method or double clamp , the current signal received by CT2 is lower than 0.5mA, will display“   “, and should check the clamping direction of the CT2 current clamp
    Interference Test
    Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
    Auxiliary Grounding Test
    With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
    Alarm Function
    Measurement value exceeds alarm setting value, will "Toot-toot-toot" alarm hint
    Battery Voltage
    While battery voltage decreases to around 7.2V±0.1V, will display battery voltage low symbol“     ”, and reminding to replace the battery
    Auto-shut off
    Automatically shut down after 15 minutes of power on
    Power Consumption
    Backlight: 25mA Max(only backlight power consumption)
    Standby:25mA Max(Backlight off after power on)
    Measurement:150mA Max(Backlight shut off)
    Weight
    Tester: 2.23kg
    Tester package: 0.915kg
    Current Clamp:1.05kg(2pcs)
    Test wires: 1.56kg(include the simple test wires)
    Auxiliary grounding rods: 0.935kg(4pcs)
    Working Temperature & Humidity
    -10

    -40

    , below 80%rh
    Storage temperature & humidity
    -20

    -60

    , below 70%rh
    Protection Level
    IP65(close the case)
    Overload Protection
    Measure earth resistance: between each interfaces of C(H)-E

    P(S)-ES,AC 280V/3 seconds
    Insulation Resistance
    Over 20MΩ(between circuit and outside shell is 500V)
    Withstanding Voltage
    AC 3700V/rms. (Between circuit and outside shell)
    Electromagnetic Features
    IEC61326(EMC)
    Protection Type
    IEC61010-1(CAT

    300V

    CAT IV 150V

    Pollution 2);
    IEC61010-031;
    IEC61557-1(Earth resistance);
    IEC61557-5(Soil resistivity);
    JJG 366-2004(Grounding resistance meter)
    JJG 1054-2009(Clamp grounding resistance meter)
    Packing :
    Meter
    1 PCS
    Meter Bag
    1 PCS
    Auxiliary Grounding Rod
    4 PCS
    Test Wires
    4PCS (Red 20m; Yellow: 10m; Green: 10m; Black:20m)
    Simple Test Wires
    2 PCS (Red 1.6m; Black 1.6m)
    Current Clamp
    2 PCS
    Monitoring sortware CD
    1 COPY
    USB Communication Cable
    1 PCS
    Special Charger
    1 PCS
    Manul/Warranty Card/Certificate
    1 SET